Skip navigation

Inspection Report from Survitec Group 6 Coveralls Oct 2016

Inspection Report from Survitec Group 6 Coveralls Oct 2016

Type: 
Corrective Action Record (CAR/SCAR)
Duration: 
Mon, 24/10/2016 (All day)
Department : 
Production Garment
Effected Process : 
Production Garment
CAR Source: 
Customer Feedback
Description : 
Customer Complain against 6 Pcs samples of flyer coveralls. Customer identify the finishing and manufacturing defects in product.
Related Customer Feedback(s): 
Customer Feedback Survitec Group 2016
Root Cause Analysis & Corrective Action Record Info
Root Cause: 
The quality inspectors are too much busy with production so they overlook the samples and did not check them properly.
Corrective Action : 
QC must stamped the product after inspection. the stamp of QC provided to Quality controller.
Required Info
Priority: 
High
Progress: 
100%
Status: 
Resolved